7
17
16 Amp System
To avoid blowing fuse in meter when testing DC output
of 16 Amp system the DC Shunt, Tool #19359 (3) is
required.
The DC Shunt must
be installed on the(negative)
terminal of the battery, Fig. 34. All connections must be
clean and secure.
1. Install shunt on negative battery terminal.
2. Insert RED test lead (1) into receptacle in
meter and connect to RED post terminal on shunt,
Fig. 34.
3. Insert BLACK test lead (2) into COM receptacle in
meter and connect to BLACK post terminal on
shunt.
4. Rotate selector to
position.
5. Attach RED test lead clip to DC output terminal on
regulator-rectifier, Fig. 34.
6. With the engine running at 3600 RPM. The output
should be:
* 3-16 Amps – 16 Amp System
* Depending upon battery voltage. A fully charged
battery will show less amperage.
7. If no output or low output is found, replace the
regulator-rectifier.
Fig. 34
3
2
1
Replacing Rectifier
1-1/2 Amp Alternator
Used on Model Series 130000
Before Date Code 91032500
NOTE:Early style rectifier box is replaced by
rectifier harness shown in Fig. 35.
1. Cut stator wires close to rectifier so that stator
wires remain as long as possible.
2. Discard old rectifier.
3. Strip insulation back 3/8” (9.5 mm) from stator
wires.
NOTE:Replacement rectifier has two exposed
wires which are already stripped of
insulation.
4. Twist and solder each stator wire to a rectifier wire.
5. Insulate each connection with electrical friction
tape or shrink tubing. Keep connected areas as
compact as possible.
6. Attach ground wire to drive housing using original
rectifier mounting screw, Fig. 22.
Fig. 35