5. Lighting Circuit (White Wire B–) Attach RED test
lead (1) clip to point “A,” Fig. 28. (It may be
necessary to pierce white wire (4) with a pin as
shown.) Insert BLACK test lead (2) probe into
harness connector.
a. If meter “Beeps” once, diode is OK.
b. If meter makes a continuous tone, diode is
defective (shorted). Replace.
c. If meter displays “OL,” proceed to step 6.
6. Reverse test leads.
a. If meter “Beeps” once, diode is installed back-
wards.
b. If meter still displays “OL,” diode is defective
(open). Replace.
“A”
Fig. 28
4
1
2
Quad Circuit Alternator
Test Charging Circuit (DC+)
NOTE:Regulator-rectifier will not function unless
it is grounded to engine. Make sure the
regulator-rectifier is securely mounted to
engine.
When testing regulator-rectifier for amperage output a
12 volt battery with a minimum charge of 5 volts is
required. There will be no charging output if battery
voltage is below 5 volts.
NOTE:Connect test leads securely before starting
engine. If a test lead vibrates loose while
engine is running, regulator-rectifier may
be damaged.
1. Insert RED test lead into 10 A receptacle in meter.
2. Inset BLACK test lead into COM receptacle in
meter.
3. Rotate selector to
(DC amps) position.
4. Attach RED test lead (1) clip to charging output pin
(3, red wire), Fig. 29.
5. Attach BLACK test lead (2) clip to positive (+)
battery terminal.
6. With engine running at 3600 RPM output should
be 3 to 5 amps. Amperage will vary with battery
voltage. A fully charged battery will show less
amperage.
7. If no output or low output is found, replace
regulator-rectifier.
Fig. 29